PV methods¶
Implemented from public descriptions of IEC 61724-1 and IEC TS 63019 and from Dierauf et al. (2013); not a certified implementation of the standards.
Performance ratio¶
With \(E_i\) the AC energy of interval \(i\), \(P_\mathrm{STC}\) the DC rating, \(G_i\) the plane-of-array irradiance, \(G_\mathrm{STC} = 1000\ \mathrm{W/m^2}\), \(\gamma\) the power temperature coefficient (1/K, negative) and \(T_{c,i}\) the cell temperature, summed over the intervals used:
The weather-corrected PR (Dierauf et al., 2013, NREL/TP-5200-57991) corrects to \(T_\mathrm{typ}\), the irradiance-weighted mean cell temperature of a typical year, instead of 25 °C:
Over the typical year itself \(\mathrm{PR}_\mathrm{wc} = \mathrm{PR}\) exactly when the plant follows the temperature model; month by month it removes the seasonal swing that \(\mathrm{PR}\) shows and that \(\mathrm{PR}_{25}\) overcorrects. Intervals with a missing power or irradiance are left out of numerator and denominator; when cell temperatures are given, intervals without one are left out of all three ratios.
Cell temperature models: from a back-of-module sensor \(T_c = T_m + G/1000 \cdot \Delta T\) (King et al., 2004, SAND2004-3535) and the PVsyst heat balance \(T_c = T_a + \alpha G (1 - \eta) / (U_c + U_v v)\).
t = pv.pr_terms(p_ac_kw, poa_wm2, p_stc_kw=146.6, interval_h=0.25, t_cell_c=t_cell, gamma_per_k=-0.0045,
t_typ_c=pv.typical_cell_temperature(poa_tmy, t_cell_tmy), mask=poa_wm2 > 50)
t.pr, t.pr_temperature_corrected, t.pr_weather_corrected
Availability¶
Units \(u\) (inverters) carry capacity weights \(w_u\), \(\sum_u w_u = 1\). An interval counts when it is daylight (irradiance above a threshold, 50 W/m² by default), the unit's state is known, and it is neither excluded nor planned maintenance within the allowance:
- Excluded periods (grid outage, grid-operator instruction, force majeure: whatever the contract places outside the operator's responsibility) leave numerator and denominator.
- Planned maintenance is excluded until its capacity-weighted daylight hours in the period exceed the allowance; afterwards it counts as downtime.
- The energy basis weighs each stopped interval by the energy the unit was expected to produce (after soiling, snow and clipping), so an outage on a sunny noon costs more than one at dawn.
Energy bridge¶
The bridge explains the difference between the budget energy \(E_b\) (e.g. P50) and the measured energy \(E_\mathrm{act}\) of a month. Its bars add up to \(E_\mathrm{act} - E_b\) exactly.
Weather steps. Ratios outside the operator's control (irradiance, temperature, degradation) re-state the budget in order:
Loss steps. For each loss \(k\) (soiling, snow, clipping, availability, curtailment, data gaps, ...) the bar is the budgeted loss minus the measured loss, in energy. Measured fractions \(\ell_k\) apply in order to the actual plant's potential, budgeted fractions \(b_k\) to the potential the budget implies for that weather:
Residual. \(E_\mathrm{act} - E_b - \sum \text{bars}\). Summing the bars shows that it always equals \(X_a - X_b\): the gap between the potential of the actual plant and the potential the budget implies for the weather that occurred, which the measurements do not explain (model error, unmodelled losses, sensor level).
Shapley variant. The month is written as a product \(E_\mathrm{act} = E_b \prod_k f_k\) of the weather ratios, the loss ratios \((1 - \ell_k)/(1 - b_k)\) and the residual factor \(X_a / X_b\). Each bar is the Shapley value of the game \(v(S) = E_b \prod_{k \in S} f_k\):
It does not depend on the order of the factors, and the bars still close exactly, but no single bar equals a measured loss. The sequential method is the default because each loss bar is then a quantity one can check.
bars = pv.energy_bridge(
e_budget=table["E_budget"], e_actual=table["E_actual"],
weather={"irradiance": table["r_irr"], "temperature": table["r_temp"], "degradation": table["r_deg"]},
losses_actual={"soiling": table["soiling"], "availability": table["unavailability"]},
losses_budget={"soiling": 0.02, "availability": 0.01},
index=table.index,
)
References¶
- Dierauf, T., Growitz, A., Kurtz, S., Becerra Cruz, J. L., Riley, E., Hansen, C. (2013). Weather-Corrected Performance Ratio. NREL/TP-5200-57991.
- King, D. L., Boyson, W. E., Kratochvil, J. A. (2004). Photovoltaic Array Performance Model. SAND2004-3535.